CFL Series – SG

Cable Fault Locator

SCOPE offers CFL Series, Cable Fault Locator Test System, the ultimate solution for locating all types of underground cable faults in minimum time, thus saving long outages and consequential revenue loss & inconvenience.SCOPE offers a full range of products required for fault location of LT/HT power and telecom cables. It includes various models of Surge Generators (Thumpers), Pre-Loca-tors, Pin-Pointers, SIM Filters and Audio Generators.The utility of Surge Generators can be further enhanced by optional in-built features like DC Hi-pot, Burn Down and Sheath Fault Locator.Appropriate models can be chosen and product configuration can be optimized based on application.Various constituent models of Cable Fault Locator Test System are:Surge Generator (Thumper): CFL SG 1605 / 1610 / 1620 / 3210 / 3215 / 3220 Pre Locator: CFL PL2 / PL2+ / PL3 / PL3+ / PL4+Pin Pointer cum Route Tracer: CFL PP3 / PP3+ Audio Generator: CFL AG2SIM Filter: CFL SIMFCable Identification System: CFL CIS Soft Discahrge Rod: CFL DDR seriesCable Fault Surge Generator: CFL SG SeriesCFL SG Series offer voltages up to 16kV / 32kV and energy up to 2000J.
  • Compact, rugged design
  • Key-lock Switch to restrict unauthorized operation
  • Variac Zero, HV Switch & Output Plug Interlock for HV circuit
  • Over-heat Protection at 70°C
  • DC Test System (Hi-Pot, Burn Down & Sheath Fault)
  • Over-current Trip – in DC Test System
  • Earth Indication Emergency Off

TECHNICAL DATA

Full Product Specifications

ParametersCFL SG 1605 / SG 1610 / SG 1620CFL SG 3210 / SG 3215 / SG 3220
Output Voltage Range0-4, 0-8, 0-16kV0-8, 0-16, 0-32kV
Output Energy500J / 1000J / 2000J1000J / 1500J / 2000J
Impulse Period SequenceSingle Impulse / 3S / 6S / 9S or other as desired
Fault Distance Measurement

Modes Supported

ICM (Impulse Current Method), SIM (Secondary Impulse Method)
Output IndicationMoving Coil Meters
Power230V AC ±10%, 50/60Hz
HousingElegant, rugged aluminium housing Or mounted on optional trolley
Dimensions532 X 422 X 654 mm700 X 700 X 900 mm
Weight (approx.)55 kg / 60 kg / 65 kg95 kg / 105 kg / 115 kg
Optional ‘DC Hi-Pot’ Mode
DC Hi-Pot RangesVoltage: 0–32kV, Current: up to 24mA
Optional ‘Burn Down’ Mode
DC Burn Down RangesVoltage: 0-8, 0-16, 0-32kV, Current: 0-240, 0-120, 0-60mA
Optional ‘Sheath Fault Locator’ Mode
DC Sheath Fault RangesVoltage: 0-8kV, Current: 0-240mA

Test Timing Intervals: Single Impulse, 3S / 6S / 9S or other as desired

Related Products

Multifunctional analyzer EVSE-100 is an instrument dedicated to diagnostics of electric vehicle charging stations and cables. Using a single device, we will perform a set of tests on these objects, ending with the generation of a professional report. Through appropriate simulation of CP and PP circuits, the meter can put the station into various operating states. This allows us to verify the correctness of the control system and perform measurements in the field of electric shock protection. We can complete the verification of functionality and safety by simulating errors on the power supply side, i.e. the charging station (ICCB), and charging side of the vehicle (CP circuit)
CFL PL Series, Cable Fault Pre-Locators from SCOPE are the ultimate solution for locating underground cable faults in minimum time.
MagD is specially designed to cater the needs of testing of Instrument Transformers. Before new systems are put into service or after any occurrence of fault, Instrument Transformers need to be tested for their outputs. It is to be ensured that Instrument Transformers give proper outputs to protection relays.
The ultimate solution for testing Loco Circuit Breakers of all types & makes. CBSCOPE checking the dynamic performance of Single bottle, Double bottle & Loco VCBs.