CFL Series – PP Series

Cable Fault Route Tracer cum Pinpointer: CFL PP Series

CFL PP series is suitable for pin-pointing of fault location as well as route tracing of any type of cable. For pinpointing it is used along with CFL SG Series Surge Generators and for route tracing it is used along-with CFL AG Series Audio Frequency Generators.
  • Can be used for both pinpointing as well as route tracing
  • Both magnetic & acoustic inputs making pinpointing very convenient (Co-incidence Method)
  • Digital filters to eliminate external noise
  • Highly sensitive magnetic signal pick up
  • Mute function for headphones to disable noise while moving
  • Live loaded cable detection with 50 Hz frequency using route tracing coil (CFL PP3+)
  • Large LCD display with backlit facility
  • Internal Li-ion chargeable battery
  • Specially made light weight case ensuring minimum strain to operator
  • Water resistant and dust proof design
  • User friendly and simple operation

TECHNICAL DATA

Full Product Specifications

ParametersCFL PP3CFL PP3+
ChannelsAcoustic and magnetic
FunctionCable Route Tracing and Fault Pin-pointingCable Route Tracing, Fault Pin-pointing and Live loaded cable detection
Operating PrincipleCoincidence Method
Gain>120dB adjustable for both Acoustic and Magnetic
Frequency Range70 Hz to 3000 Hz with automatic filtering
Headphone3.5mm jack
Rechargeable Battery7.4 V Li-ion11.1 V Li-ion
Power supply90V-270V AC, 50/60 Hz
Display5’’,Monochrome backlit LCD,240 x 128 pixel5.7’’, TFT Touch Screen, 320 x 240 pixel
Environmental-10 °C to 55°C, 95% RH (Non-Condensing)
Dimension230 x 140 x 170 mm231 x 90 x 135 mm
Weight1.5 kg1.2 kg

Related Products

3″ Line Post, Standard Leak, Two Hole Blade, Steel Flat Base with 8″x10″ holes for 3/4″ bolts, 9″x13″ holes for 7/8″ bolts, and 14″ CL holes for 1″ bolts.The Quadri*Sil® transmission line post insulator embodies the latest in polymer insulator design that combines a patented revolutionary four-point sealing system together with electrical grade corrosion resistant direct draw fiberglass rod and proprietary silicone polymer to provide the highest quality, lab tested, and field proven insulator on the market with a 3″ core rod for increased mechanical strength.Made from hydrophobic silicone polymer
Professional meter for photovoltaic installations up to 1500 VThe PVM-1530 is a pioneering meter for photovoltaic installations up to 1500 V with such a substantial number of measurement functions. It can be used for category 1 measurements according to EN 62446-1. It allows the measurement of the I-U curve for category 2 according to EN 62446-1. Furthermore, it also converts measured parameters into STC conditions according to EN IEC 60891. Comprehensive, yet simple to use, it flawlessly performs its tasks in monitoring the safety and efficiency parameters of photovoltaic (PV) installations.
HPT Series Hi-Pot Test Sets is available in three different combinations, viz., Power Frequency AC, DC and AC-DC Combined HV Test Sets for testing of transformers, motors, insulators, cables etc. Further, these test sets are capable of giving continuously variable HV from zero to maximum rated output voltage.HPT Series testers are specifically designed for safe and accurate measurement of leakage current to evaluate insulation integrity. These testers are moveble, one end ground test systems, ideal for HV testing. Accurate leakage measurements are ensured by placing the current meter in the return path of the HV. Years of Design, engineering and manufacturing experience have made our HPT testers the most durable, easily operated and the best designed sets in the segment. The product has been designed considering the importance of safety of the operator. The kit has various interlock to avoid any kind of accident while doing the high voltage testing.
SCOPE’s Single Phase (TTRM 101 / TTRM 102) and Three Phase (TTRM 301 / TTRM 302), Transformer Turns Ratio Meters are rugged yet light weight and highly reliable instruments to measure turns ratio of transformers in live switchyards up to 765kV.TTRM is equally suitable for use on manufacturing shop floor and test laboratories. It can be used for testing of single / three phase power transformers (star or delta connected, with or without neutral), CTs and PTs.