CBSCOPE

Loco Circuit Breaker Test System

The ultimate solution for testing Loco Circuit Breakers of all types & makes. CBSCOPE checking the dynamic performance of Single bottle, Double bottle & Loco VCBs.
  • CBSCOPE Measures timings, bounce and simultaneity of contacts
  • Analyses contact travel characteristics for speed, contact gap, over-travel and rebound
  • Records trip / holding and close coil current characteristics
  • Displays settings, graphical and tabulated test results, also prints test report on external printer (optional)
  • Incorporates powerful Windows based Test Manager Software to control / operate instrument and also to view and analyse the test data on optional laptop / computer
  • Specially designed test commands for all Loco VCB testing in-built
  • Analysis of test result provides inputs to assess and correct
    • Settings for contact timings
    • Closing and Opening speed, over-travel, rebound and contact gap
    • Trip / Close release mechanism setting

TECHNICAL DATA

Full Product Specifications

ChannelsConfigurationRangeResolutionAccuracy
Contact Timing Channels3 : 2 for double bottle VCB, 1 spareMeasurement duration

1mS to 40S @ 1kC,

0.05mS to 2S @ 20kC

1mS at 1kC 0.05mS at 20kCValue ± 0.05%

± 1 digit

Coil Current

Channels

2 : Trip / Holding &

Close Coil current

1, 2, 5, 10, 25 A DC0.1% of range at 1A,

0.004% of range at 25A

Value ± 0.5%

± 1 digit

Travel Channels2 : Travel

Characteristics

0 – 5V DC1.2mV at 25AValue ± 0.5%

± 1 digit

  • Breaker Control : Two solid state contacts rated at 35A, 300V AC/DC for breaker operation (Close & Trip)
  • Trigger Options : Loco breaker C, O and for other breakers C, O, C-O, O-C, O-C-O with configurable delay
  • Sampling Speed : 20kC, 10kC, 5kC, 2kC & 1kC selectable
  • Travel Channels : For linear / rotary resistive transducers, 0-5V DC excitation source in-built
  • Communication Port : Ethernet port for communication between laptop and instrument
  • Power : 110 V/230V AC ± 15%, 50/60 Hz ± 10%, supplied with suitable Test Leads & Aluminium Transport Case

Related Products

3″ Line Post, Standard Leak, Two Hole Blade, Steel Flat Base with 8″x10″ holes for 3/4″ bolts, 9″x13″ holes for 7/8″ bolts, and 14″ CL holes for 1″ bolts.The Quadri*Sil® transmission line post insulator embodies the latest in polymer insulator design that combines a patented revolutionary four-point sealing system together with electrical grade corrosion resistant direct draw fiberglass rod and proprietary silicone polymer to provide the highest quality, lab tested, and field proven insulator on the market with a 3″ core rod for increased mechanical strength.Made from hydrophobic silicone polymer
Multifunctional analyzer EVSE-100 is an instrument dedicated to diagnostics of electric vehicle charging stations and cables. Using a single device, we will perform a set of tests on these objects, ending with the generation of a professional report. Through appropriate simulation of CP and PP circuits, the meter can put the station into various operating states. This allows us to verify the correctness of the control system and perform measurements in the field of electric shock protection. We can complete the verification of functionality and safety by simulating errors on the power supply side, i.e. the charging station (ICCB), and charging side of the vehicle (CP circuit)
Battery banks have become an inseparable part of uninterrupted or back-up power supply arrangements in various industries like Power, Telecom, IT etc. In substations the critical protection, control & communication systems run on battery power. Hence the reliability of these battery banks is crucial to ensure smooth operation of equipment which they are serving. The capacity of battery may get reduced significantly before the expected life span of battery due to various reasons. The only way to assess the continual health of battery banks is periodical maintenance inspection & testing. Conducting a discharge test on batteries is most effective way to check the battery capacity.SCOPE introduces BLUe Series Battery Loading Units; these are moveble instruments for controlled & monitored discharge of batteries. They are designed for integrated site discharge test, design & QC test and also for monitoring discharge process of battery bank with connected load. Each single autonomous unit having built-in display, keypad and wireless communication with computer makes it very easy to use. It comes in different configurations ranging from 12V to 380V discharge voltages and 50A to 300A discharge currents.Various options are available to control & monitor the discharge process. With the help of optional Cell Monitoring Unit – CellMon, voltage of each individual cell can be monitored & data sent to main BLUe unit and then from main unit to computer via wireless communication. Each BLUe unit is supplied with computer downloading & analysis software for real time monitoring of discharge process.
Prima Series is designed for Primary Current Injection Testing of Current Transformers, Protection Relays & Circuit Breakers during their Factory Test, Commissioning and Routine Testing. It is also used to test the Turns Ratio of Current Transformers and for other applications that require variable high currents. The Kit is designed for most optimal use of man and machine and is suitable to work in live switchyard conditions. Prima consists of a Control Unit and a low weight Loading Transformer, enabling the user to take the Loading Transformer nearest to the CT terminal. Thus, the weight of both the output lead and overall kit reduces considerably. The innovative design of Prima gives the ultimate flexibility to the user to use the full capacity of the Loading Transformer by adjusting the output voltage and current as per requirement.